Material Uplift in Faraday Lithium Grades
Released
Released
Announcement PDF
ASX Announcement
26 October 2023
Material Uplift in Faraday Lithium Grades
Highlights
•
Re-assaying of drill samples from Faraday has returned materially higher lithium results than
previously reported.
•
3,371 samples re-assayed.
•
Results have produced up to a 64% increase in lithium grade.
•
Assay results to form part of a materially enhanced Mineral Resource Estimate (MRE) at Faraday
and a maiden MRE at Trainline.
•
Results confirm shallow, continuous and higher-grade mineralisation at both deposits in the
heart of the Kambalda lithium corridor.
Illustration of Grade Uplift from Previously Reported Intercepts:
Hole ID
Prospect
Depth From
(m)
Depth to
(m)
Interval
(m)
4-Acid
Li2O%
Fusion
Li2O%
Diff.
23MERC014*
Faraday
13
26
13
0.87
1.12
29%
23MERC056*
Faraday
4
16
12
0.91
1.28
41%
23MERC062*
Faraday
21
31
10
0.62
0.80
29%
23MERC080*
Faraday
31
37
6
0.90
1.47
63%
23MERC118#
Trainline
17
26
9
0.82
1.19
45%
23MERC132# Trainline
137
142
5
0.69
*
Widgie Fast-tracks Faraday Lithium Deposit for DSO Opportunity. Released 14/02/2023
#
New Lithium Discoveries Position Widgie for Resource Growth. Released 4/07/2023
0.91
32%
Widgie Nickel’s Managing Director and CEO, Mr Steve Norregaard, commented:
“Our lithium plans have received an important boost with these results which has led to both an uplift
in scale and grade of our lithium resources which we expect to quantify in the very near future.
“We are now prioritising an updated Mineral Resource Estimate (MRE) for Faraday and a maiden MRE
at the Trainline prospect. With mining approvals in place, proven and favourable metallurgy set to
provide Widgie with multiple opportunities to demonstrate the value of its lithium endowment in the
near future.”
Widgie Nickel Ltd (ASX: WIN) (“Widgie” or “the Company”) is pleased to provide an update on its
Faraday Lithium Project (“Faraday”) and Trainline Prospect (Trainline).
ABN 77 648 687 094
Level 4, 220 St Georges Tce
Perth, WA 6000
PO BOX 7713
Cloisters Square WA 6850
T: +61 8 6381 7250
F: +61 8 6381 7299
info@widgienickel.com.au
www.widgienickel.com.au
1
ASX Announcement
26 October 2023
Re-assaying Expected to Result in MRE Grade Increase
The Company concluded drilling used in calculating the maiden Mineral Resource Estimate (MRE) for
Faraday in January 2023.
However, assay results from subsequent diamond holes at Faraday that had been drilled for
metallurgical testwork twinning existing reverse circulation (RC) holes suggested a discrepancy
between the diamond and the RC results. An internal investigation concluded the initial assaying
methodology recommended by the laboratory was inappropriate for Faraday mineralisation.
A comprehensive re-assaying program of 3,371 samples of mineralisation has confirmed a positive bias
using a fusion method. This assay issue applied to exploration/step out drilling along with recently
completed 10m x 10m grade control drilling within the proposed Faraday pit shell and intial
reconnaisance drilling to the north which delineated the Trainline prospect.
Based on the latest results, and subsequent drilling on each deposit it is expected that recalculation
of the MRE for Faraday and inclusion of Trainline will result in a materially higher lithium grade and
increase in size.
Background
An initial sample analysis on 18 drillholes (MERC241-MERC258) in 2022 at Faraday was completed by
Nagrom Commercial Laboratory (Nagrom) in Kelmscott, Western Australia. Nagrom carried out a twostage analysis process utilising a Peroxide Fusion with ICP-OES finish for Li, B, Be, Cs, Rb and a Li
Borate Fusion with XRF finish for Al, Ba, Ca, Fe, K, Mg, Mn, Nb, P, S, Sn, Sr, Ta, W.
In January 2023, Intertek Genalysis (Intertek) was engaged for intial work focussing on lithium analysis.
Upon receiving the first samples, Intertek was unable to complete the work using the fusion method
due to lack of availability of nickel crucibles required for this process. Instead, Intertek recommended
Widgie use an alternative 4-Acid digest method as an appropriate substitute.
On this recommendation, the Company proceeded with submitting 1,198 samples to Intertek to be
assayed.
The 4-Acid assay results, along with 485 sample assays received initially from Nagrom, were combined
to inform the maiden MRE for the Faraday Lithium Project of 481kt @ 0.59% Li 2 O (0.30% Li 2 O cut-off).
All QA/QC standards, blanks and field duplicates performed satisfactorily for both 4-Acid and Fusion
methods (Refer Competent Person Statement for the Mineral Resource Estimate as released to the ASX
on 29 March 2023).
Intertek subsequently secured nickel crucibles in April 2023 and were able to perform Fusion analyses
thereafter. The Company then commenced using the Fusion method in tandem with the 4-Acid
Digestion method.
The Company initiated a review comparing assay results between the 4-Acid and Fusion methods by
re-submitting in aggregate 651 pulp samples for Fusion analysis at Intertek that had originally been
assayed via the 4-Acid method.
ABN 77 648 687 094
Level 4, 220 St Georges Tce
Perth, WA 6000
PO BOX 7713
Cloisters Square WA 6850
T: +61 8 6381 7250
F: +61 8 6381 7299
info@widgienickel.com.au
www.widgienickel.com.au
2
ASX Announcement
26 October 2023
The results demonstrated a significant bias, as previously reported (refer ASX announcement – 27
September 2023 - Higher grade Lithium to come on the cusp of being shovel ready at Faraday). The
updated Q-Q Plot (Figure 1 below) represents all returned Fusion samples (3,371) supporting a positive
bias towards the Fusion method.
The Company and Intertek have agreed that the 4-Acid methodology was not appropriate for assaying
Faraday & Trainline’s lithium mineralisation. All mineralised intervals that were previously analysed
using the 4-Acid method have now been re-assayed via the Fusion method.
A full list of comparative assays, not previously reported, is provided in the following Table 2.
Figure 1 Q-Q plot demonstrating grade bias towards Fusion method (red line indicates perfect correlation, 1:1 relationship)
Faraday Location
The Faraday-Trainline Lithium Project area is located on Mining Lease M15/102, 4km west north-west
of the Widgiemooltha townsite. Access is via the Coolgardie-Norseman Rd, 63km south of Coolgardie.
Faraday is central to Widgie’s Mt Edwards Project, covering a significant land holding within the
“Lithium Corridor” between Mt Marion to the north and Pioneer Dome to the south (Figure 2).
ABN 77 648 687 094
Level 4, 220 St Georges Tce
Perth, WA 6000
PO BOX 7713
Cloisters Square WA 6850
T: +61 8 6381 7250
F: +61 8 6381 7299
info@widgienickel.com.au
www.widgienickel.com.au
3
ASX Announcement
26 October 2023
Figure 2 Regional Geology showing Faraday and Trainline Lithium Project location, and surrounding Lithium Projects
Geology and Lithium Mineralisation
The Mt Edwards Project lithium tenements cover the northern margin of the Widgiemooltha Dome. The
mineralisation at the Faraday-Trainline Lithium Project is hosted within Lithium-Caesium-Tantalum
(LCT) pegmatites associated with a late-stage fractionated granitic intrusions.
The stacked pegmatites intrusives are hosted steeply dipping mafic/ultramafic country rock. The
pegmatites are shallowly dipping to the west at 20 o and are found to be outcropping in places. The
pegmatite widths vary from 1m to 14m in thickness, with greater thicknesses observed within the
ultramafic host. The pegmatites have been mapped over a strike extent of 750m from north-south and
remain open at depth.
ABN 77 648 687 094
Level 4, 220 St Georges Tce
Perth, WA 6000
PO BOX 7713
Cloisters Square WA 6850
T: +61 8 6381 7250
F: +61 8 6381 7299
info@widgienickel.com.au
www.widgienickel.com.au
4
ASX Announcement
26 October 2023
Competent Person Statement – Exploration Results
The information in this announcement that relates to exploration results and sampling techniques is
based on and fairly represents information and supporting documentation compiled by Mr William
Stewart, who is a full-time employee of Widgie Nickel Limited. Mr Stewart is a member of the Australian
Institute of Metallurgy and Mining (member no 224335) and Australian Institute of Geoscientists
(member no 4982). Mr Stewart has sufficient experience that is relevant to the style of mineralisation
and type of deposit under consideration and to the activity being undertaken to qualify as a Competent
Person as defined in the 2012 Edition of the ‘Australasian Code for Reporting of Exploration Results,
Mineral Resources and Ore Reserves’. Mr Stewart consents to the inclusion in the report of the matters
based on his information in the form and context in which it appears.
Compliance Statement
The information in this report that relates to Exploration Results are extracted from the ASX
Announcements listed in the table below, which are also available on the Company’s website
www.widgienickel.com.au.
Table 1 Compliance Statement
Date
Title
08/12/2022
Initial Assays Confirm High Grade Lithium Discovery at Faraday
09/01/2023
Further Assays Reaffirm High-grade Lithium Discovery at Faraday
14/02/2023
Widgie Fast-tracks Faraday Li2O Deposit for DSO Opportunity
29/03/2023
Maiden Resource Proves Up Faraday DSO Stater Pit Opportunity
08/05/2023
Faraday Mining Proposal Lodged
04/07/2023
New lithium Discoveries Position Widgie for Resource Growth
02/08/2023
Faraday Metallurgical Testwork-Excellent Flotation Response
04/08/2023
Faraday Mining Proposal Approved
27/09/2023
Higher grade Lithium to come on the cusp of being shovel ready at Faraday
02/10/2023
Drilling Delivers High-grade Lithium at Trainline
27/10/2023
Higher grade Lithium to come on the cusp of being shovel ready at Faraday
The Company confirms that it is not aware of any new information or data that materially affects the
information included in the original market announcements and that all material assumptions and
technical parameters underpinning the estimates in the market announcements continue to apply and
have not materially changed. The Company confirms that the form and context in which the Competent
Persons’ findings are presented have not been materially modified from the original market
announcements.
ABN 77 648 687 094
Level 4, 220 St Georges Tce
Perth, WA 6000
PO BOX 7713
Cloisters Square WA 6850
T: +61 8 6381 7250
F: +61 8 6381 7299
info@widgienickel.com.au
www.widgienickel.com.au
5
ASX Announcement
26 October 2023
Approved by: Board of Widgie Nickel Ltd
-ENDS-
For further details please contact
Media & Broker Inquiries:
Steve Kaless
White Noise Communications
steve@whitenoisecomms.com
+618 6556 8614
Steve Norregaard
Managing Director
steve@widgienickel.com.au
0472 621 529
Table 2 Previously reported 4-Acid versus new Fusion Assay Results
Hole ID
Prospect
23MERC001
23MERC002
23MERC003
incl.
incl.
23MERC004
23MERC005
23MERC006
23MERC007
23MERC008
23MERC009
23MERC010
23MERC011
23MERC012
incl.
23MERC013
incl.
23MERC014
incl.
23MERC015
23MERC016
23MERC017
incl.
23MERC018
and
23MERC019
incl.
23MERC020
23MERC021
23MERC022
23MERC023
incl.
23MERC024
23MERC025
23MERC026
23MERC027
incl.
incl.
23MERC028
23MERC029
23MERC030
Faraday
Faraday
Faraday
Faraday
Faraday
Faraday
Faraday
Faraday
Faraday
Faraday
Faraday
Faraday
Faraday
Faraday
Faraday
Faraday
Faraday
Faraday
Faraday
Faraday
Faraday
Faraday
Faraday
Faraday
Faraday
Faraday
Faraday
Faraday
Faraday
Faraday
Faraday
Faraday
Faraday
Faraday
Faraday
Faraday
Faraday
Faraday
Faraday
Faraday
Faraday
ABN 77 648 687 094
Level 4, 220 St Georges Tce
Perth, WA 6000
Depth From
(m)
Depth to
(m)
Interval
(m)
4-Acid
Li2O%
Fusion
Li2O%
Announcement
date
4
2
5
6
10
6
8
15
30
6
4
13
7
13
14
18
25
38
NSI
6
10
6
17
17
24
20
26
26
14
12
25
21
17
31
34
33
12
15
16
15
11
20
26
11
17
6
17
12
21
20
2
2
8
1
3
8
10
10
8
1.15
0.89
0.75
1.10
0.95
0.94
0.82
1.04
0.65
1.39
1.01
0.87
1.33
1.16
1.15
0.89
1.33
0.88
5
10
5
11
5
16
7
13
3
10
4
15
7
3
9
15
10
5
14
10
7
2
3
7
2
14
3
6
6
13
4
0.61
0.58
0.61
0.77
1.00
0.74
1.02
0.87
1.28
0.39
0.94
0.66
1.08
0.67
0.79
0.84
1.00
0.87
0.30
0.30
0.66
1.07
0.37
0.68
0.74
0.57
0.80
0.77
0.75
0.37
0.63
0.84
0.74
0.79
0.94
1.20
0.88
1.20
1.12
1.54
0.53
1.26
0.85
1.39
0.72
0.95
0.95
1.12
1.04
0.35
0.37
0.97
1.58
0.49
0.86
0.92
0.73
1.07
0.95
0.99
0.50
0.85
14/02/2023
14/02/2023
14/02/2023
14/02/2023
14/02/2023
14/02/2023
14/02/2023
14/02/2023
14/02/2023
14/02/2023
14/02/2023
14/02/2023
14/02/2023
14/02/2023
14/02/2023
14/02/2023
14/02/2023
14/02/2023
14/02/2023
14/02/2023
14/02/2023
14/02/2023
14/02/2023
14/02/2023
14/02/2023
14/02/2023
14/02/2023
14/02/2023
14/02/2023
14/02/2023
14/02/2023
14/02/2023
14/02/2023
14/02/2023
14/02/2023
14/02/2023
14/02/2023
14/02/2023
14/02/2023
14/02/2023
14/02/2023
1
0
1
6
12
8
13
13
23
4
8
10
16
14
22
19
23
7
1
6
8
9
17
19
9
3
3
11
6
8
16
PO BOX 7713
Cloisters Square WA 6850
T: +61 8 6381 7250
F: +61 8 6381 7299
info@widgienickel.com.au
www.widgienickel.com.au
6
ASX Announcement
26 October 2023
Hole ID
Prospect
23MERC031
23MERC032
23MERC033
23MERC034
incl.
incl.
23MERC035
23MERC036
23MERC037
23MERC038
23MERC039
incl.
23MERC040
incl.
23MERC041
and
23MERC042
23MERC043
incl.
23MERC044
23MERC045
23MERC046
23MERC047
incl.
incl.
23MERC048
23MERC049
and
23MERC050
23MERC051
23MERC052
and
incl.
23MERC053
23MERC054
23MERC055
23MERC056
incl.
incl.
23MERC057
23MERC058
23MERC059
23MERC060
23MERC061
23MERC062
and
incl.
and
23MERC063
23MERC064
23MERC065
23MERC066
23MERC067
Faraday
Faraday
Faraday
Faraday
Faraday
Faraday
Faraday
Faraday
Faraday
Faraday
Faraday
Faraday
Faraday
Faraday
Faraday
Faraday
Faraday
Faraday
Faraday
Faraday
Faraday
Faraday
Faraday
Faraday
Faraday
Faraday
Faraday
Faraday
Faraday
Faraday
Faraday
Faraday
Faraday
Faraday
Faraday
Faraday
Faraday
Faraday
Faraday
Faraday
Faraday
Faraday
Faraday
Faraday
Faraday
Faraday
Faraday
Faraday
Faraday
Faraday
Faraday
Faraday
Faraday
ABN 77 648 687 094
Level 4, 220 St Georges Tce
Perth, WA 6000
Depth From
(m)
Depth to
(m)
Interval
(m)
4-Acid
Li2O%
Fusion
Li2O%
Announcement
date
17
26
26
29
NSI
12
4
11
17
19
21
23
28
24
14
9
6
20
21
20
15
29
12
17
17
8
15
24
7
19
8
6
8
21
15
8
12
18
16
7
13
NSI
NSI
28
45
40
6
31
26
40
NSI
7
13
16
5
9
3
0.67
0.58
0.81
0.76
9
1
1
9
10
9
10
10
1
12
3
2
11
9
12
4
12
11
13
10
1
4
8
1
7
7
6
2
9
3
4
8
7
12
2
2
0.59
1.30
1.12
0.48
0.34
0.74
0.67
0.39
1.73
0.68
1.09
0.78
0.43
0.49
0.73
1.13
0.43
0.48
0.36
0.62
1.00
0.99
0.77
1.01
0.56
0.51
1.11
0.98
0.47
0.75
0.58
0.55
0.71
0.91
1.45
1.36
0.71
1.48
1.43
0.62
0.55
1.03
0.96
0.48
1.98
0.88
1.48
0.87
0.53
0.58
0.96
1.46
0.54
0.58
0.45
0.79
1.11
1.33
1.15
1.27
0.63
0.59
1.28
1.04
0.61
0.93
0.77
0.76
0.98
1.28
2.04
1.72
9
13
8
1
10
2
2
0.26
0.27
0.47
1.95
0.62
1.00
0.77
0.34
0.33
0.68
2.48
0.80
1.22
0.88
7
7
6
3
0.25
0.41
0.52
0.51
0.32
0.53
0.70
0.52
14/02/2023
14/02/2023
14/02/2023
14/02/2023
14/02/2023
14/02/2023
14/02/2023
14/02/2023
14/02/2023
14/02/2023
14/02/2023
14/02/2023
14/02/2023
14/02/2023
14/02/2023
14/02/2023
14/02/2023
14/02/2023
14/02/2023
14/02/2023
14/02/2023
14/02/2023
14/02/2023
14/02/2023
14/02/2023
14/02/2023
14/02/2023
14/02/2023
14/02/2023
14/02/2023
14/02/2023
14/02/2023
14/02/2023
14/02/2023
14/02/2023
14/02/2023
14/02/2023
14/02/2023
14/02/2023
14/02/2023
14/02/2023
14/02/2023
14/02/2023
14/02/2023
14/02/2023
14/02/2023
14/02/2023
14/02/2023
14/02/2023
14/02/2023
14/02/2023
14/02/2023
14/02/2023
3
3
10
8
9
12
13
18
23
2
6
4
9
12
8
11
17
1
4
7
7
11
16
6
12
1
0
6
12
12
4
4
11
4
5
11
19
32
32
5
21
24
38
0
6
10
2
PO BOX 7713
Cloisters Square WA 6850
T: +61 8 6381 7250
F: +61 8 6381 7299
info@widgienickel.com.au
www.widgienickel.com.au
7
ASX Announcement
26 October 2023
Hole ID
Prospect
and
23MERC068
23MERC069
23MERC079
23MERC080
23MERC106
23MERC107
23MERC108
23MERC109
incl.
23MERC110
incl.
23MERC111
23MERC112
23MERC113
incl.
23MERC114
incl.
23MERC115
23MERC116
23MERC117
23MERC118
and
incl.
23MERC119
and
23MERC120
23MERC121
23MERC122
23MERC123
23MERC124
23MERC125
23MERC126
23MERC127
23MERC128
23MERC129
and
23MERC130
incl.
23MERC131
incl.
and
23MERC132
and
incl.
23MERC133
23MERC134
23MERC135
23MERC136
23MERC137
23MERC138
23MERC139
23MERC140
Faraday
Faraday
Faraday
Faraday
Faraday
Trainline
Trainline
Trainline
Trainline
Trainline
Trainline
Trainline
Trainline
Trainline
Trainline
Trainline
Trainline
Trainline
Trainline
Trainline
Trainline
Trainline
Trainline
Trainline
Trainline
Trainline
Trainline
Trainline
Trainline
Trainline
Trainline
Trainline
Trainline
Trainline
Trainline
Faraday
Faraday
Faraday
Faraday
Faraday
Faraday
Faraday
Faraday
Faraday
Faraday
Faraday
Faraday
Faraday
Trainline
Trainline
Trainline
Trainline
Trainline
ABN 77 648 687 094
Level 4, 220 St Georges Tce
Perth, WA 6000
Depth From
(m)
Depth to
(m)
Interval
(m)
4-Acid
Li2O%
Fusion
Li2O%
Announcement
date
14
21
4
12
31
19
27
18
16
37
NSI
NSI
NSI
43
42
51
50
NSI
NSI
37
33
53
50
64
NSI
NSI
6
26
26
13
52
74
NSI
NSI
NSI
NSI
NSI
NSI
NSI
79
24
95
100
98
102
101
109
132
142
140
104
NSI
NSI
NSI
NSI
NSI
NSI
NSI
5
6
14
4
6
0.78
0.50
0.25
0.87
0.90
1.00
0.76
0.36
1.16
1.47
4
1
9
2
0.59
0.92
0.47
0.87
0.73
1.19
0.53
0.94
7
3
10
7
3
0.61
0.94
0.68
0.79
0.44
0.7
1.17
0.88
1.02
0.52
2
9
4
5
14
7
0.86
0.82
1.19
0.60
0.41
0.35
1.19
1.19
1.63
0.77
0.56
0.42
2
1
3
3
1
3
1
4
2
5
3
4
0.49
0.89
0.63
0.38
0.73
0.63
1.20
0.47
0.55
0.69
0.87
0.36
0.68
1.05
0.63
0.41
0.81
0.74
1.43
0.64
0.62
0.91
1.14
0.35
14/02/2023
14/02/2023
14/02/2023
14/02/2023
14/02/2023
4/07/2023
4/07/2023
4/07/2023
4/07/2023
4/07/2023
4/07/2023
4/07/2023
4/07/2023
4/07/2023
4/07/2023
4/07/2023
4/07/2023
4/07/2023
4/07/2023
4/07/2023
4/07/2023
4/07/2023
4/07/2023
4/07/2023
4/07/2023
4/07/2023
4/07/2023
4/07/2023
4/07/2023
4/07/2023
4/07/2023
4/07/2023
4/07/2023
4/07/2023
4/07/2023
4/07/2023
4/07/2023
4/07/2023
4/07/2023
4/07/2023
4/07/2023
4/07/2023
4/07/2023
4/07/2023
4/07/2023
4/07/2023
4/07/2023
4/07/2023
4/07/2023
4/07/2023
4/07/2023
4/07/2023
4/07/2023
39
41
42
48
30
30
43
43
61
4
17
22
8
38
67
77
23
92
97
97
99
100
105
130
137
137
100
PO BOX 7713
Cloisters Square WA 6850
T: +61 8 6381 7250
F: +61 8 6381 7299
info@widgienickel.com.au
www.widgienickel.com.au
8
ASX Announcement
26 October 2023
Hole ID
Prospect
Depth From
(m)
Depth to
(m)
Interval
(m)
4-Acid
Li2O%
Fusion
Li2O%
23MERC141
Trainline
NSI
23MERC142
Trainline
46
48
2
0.35
0.37
23MERC143
Trainline
NSI
23MERC144
Trainline
NSI
23MERC145
Trainline
54
56
2
0.45
0.47
and
Trainline
61
68
7
0.36
0.36
23MERC146
Trainline
NSI
23MERC147
Trainline
NSI
23MERC148
Trainline
NSI
23MERC149
Trainline
109
111
2
0.51
0.68
23MERC150
Trainline
NSI
23MERC205
Trainline
NSI
23MERC206
Trainline
NSI
23MERC207
Trainline
NSI
Drill hole details have been previously reported in:
Widgie Fast-tracks Faraday Lithium Deposit for DSO Opportunity. Released 14/02/2023
New Lithium Discoveries Position Widgie for Resource Growth. Released 4/07/2023
ABN 77 648 687 094
Level 4, 220 St Georges Tce
Perth, WA 6000
PO BOX 7713
Cloisters Square WA 6850
T: +61 8 6381 7250
F: +61 8 6381 7299
Announcement
date
4/07/2023
4/07/2023
4/07/2023
4/07/2023
4/07/2023
4/07/2023
4/07/2023
4/07/2023
4/07/2023
4/07/2023
4/07/2023
4/07/2023
4/07/2023
4/07/2023
info@widgienickel.com.au
www.widgienickel.com.au
9
ASX Announcement
26 October 2023
Table 1 information in accordance with JORC 2012: Mt Edwards Lithium Exploration
Section 1 Sampling Techniques and Data
(Criteria in this section apply to all succeeding sections.)
Section 1 Sampling Techniques and Data
Criteria
JORC Code Explanation
Commentary
Sampling
techniques
Nature and quality of sampling (e.g., cut channels,
random chips, or specific specialised industry
standard measurement tools appropriate to the
minerals under investigation, such as down hole
gamma sondes, or handheld XRF instruments, etc).
These examples should not be taken as limiting the
broad meaning of sampling
No new exploration drilling data is discussed in this report. 137 RC
drill holes have been previously reported at Faraday Lithium Project.
Include reference to measures taken to ensure
sample representivity and the appropriate
calibration of any measurement tools or systems
used.
Aspects of the determination of mineralisation that
are Material to the Public Report. In cases where
‘industry standard’ work has been done this would
be relatively simple (e.g., ‘reverse circulation drilling
was used to obtain 1 m samples from which 3 kg
was pulverised to produce a 30 g charge for fire
assay’). In other cases, more explanation may be
required, such as where there is coarse gold that
has inherent sampling problems. Unusual
commodities or
mineralisation types (e.g., submarine nodules) may
warrant disclosure of detailed information.
Assays from 111 RC grade control drill holes at Faraday have been
used to inform this report. Grade control drilling results are not
considered to be material and therefore, not reported.
All drilling discussed in this report is in relation to Reverse Circulation
(RC) drilling completed at the Faraday and Trainline Lithium Project
between November 2022 and August 2023.
All RC samples have been acquired at one metre intervals from a
chute beneath a cyclone on the RC drill rig. Sample size was then
reduced through a cone sample splitter. Two identical sub-samples
have been captured in pre-numbered calico bags, with typical
masses ranging between 2 and 3.5kg. Care was taken to ensure that
both original sub-samples and duplicate sub-samples have been
collected representatively, and therefore are of equal quantities. The
remainder of the sample reject is retained in the short term in sample
piles at the drill site.
All samples were submitted for assay at single metre sample
intervals. With samples crushed, rotary split, pulverised to produce
a homogenised 50-100g pulp sample ready for analysis.
With sampling of the prospective pegmatite vein and 2-5m into the
mafic/ultramafic waste rock host to ensure representative sampling.
No other measurement tools related to sampling have been used in
the holes for sampling other than directional/orientation survey
tools.
Details of the two analysis methods outlined in this report are as
follows.
Primary samples were assayed by;A four-acid (4-Acid method) digest. With an Inductively Coupled
Plasma Optical Emission Spectrometry (ICP-OES) finish for Li only.
The 3,371 pulp samples were re-submitted for comparison to the 4Acid method in relation to this report were assayed by;-
Drilling
Techniques
Drill type (e.g., core, reverse circulation, open- hole
hammer, rotary air blast, auger, Bangka, sonic, etc)
and details (e.g., core diameter, triple or standard
tube, depth of diamond tails, face-sampling bit or
other type, whether core is oriented and if so, by
what method, etc).
ABN 77 648 687 094
Level 4, 220 St Georges Tce
Perth, WA 6000
PO BOX 7713
Cloisters Square WA 6850
A sodium peroxide fusion (Fusion method) using nickel crucibles and
hydrochloric acid to digest. With an Inductively Coupled Plasma
Optical Emission Spectrometry (ICP-OES) finish for Al, B, Ba, Be, Ca,
Cs, Fe, K, Li, Mg, Mn, Nb, P, Rb, S, Si, Sn, Sr, Ta and W.
One hundred and thirty seven (137) RC drillholes and have been
previously reported at Faraday-Trainline Lithium Project for 8,026m
drilled. 3,371 RC samples were submitted (exploration and grade
control) for re-assay outlined in this report.
The RC rig is a KWL350 with a face sampling auxiliary compressor
and booster. Drill rods are 6 metres long and face sampling drill bit
diameter of 143mm, and hence so is the size of drillhole diameter.
T: +61 8 6381 7250
F: +61 8 6381 7299
info@widgienickel.com.au
www.widgienickel.com.au
10
ASX Announcement
26 October 2023
Section 1 Sampling Techniques and Data
Holes have been drilled at a nominal dip angle of -60° with varying
azimuth angles to orthogonally intercept the interpreted favourable
geological contact zones.
Drill
Sample
Recovery
Logging
Method of recording and assessing core and chip
sample recoveries and results assessed.
Measures taken to maximise sample recovery and
ensure representative nature of the samples.
Whether a relationship exists between sample
recovery and grade and whether sample bias may
have occurred due to preferential loss/gain of
fine/coarse material.
Whether core and chip samples have been
geologically and geotechnically logged to a level of
detail to support appropriate Mineral Resource
estimation, mining studies and metallurgical
studies.
Whether logging is qualitative or quantitative in
nature. Core (or costean, channel, etc) photography.
Subsampling
techniques
and sample
preparation
The total length and percentage of the relevant
intersections logged.
If core, whether cut or sawn and whether quarter,
half or all core taken.
If non-core, whether riffled, tube sampled, rotary
split, etc and whether sampled wet or dry.
For all sample types, the nature, quality and
appropriateness of the sample preparation
technique.
The sample recovery is logged by a geologist during drilling, and
recoveries have been considered acceptable. With all sampling
being dry.
Minor sample loss was recognised while sampling the first metre of
some drillholes due to very fine grain size of the surface and nearsurface material.
No relationship between sample recovery and grade has been
recognised.
All RC drillholes have been geologically logged for lithology,
weathering, alteration, and mineralogy.
All samples have been logged in the field at the time of drilling and
sampling (both quantitatively and qualitatively where viable), with
spoil material and sieved rock chips assessed. All RC holes and chip
trays are photographed.
Geochemical analysis of each hole has been correlated back to
logged geology for validation.
No core drilling was undertaken for this report.
The sample preparation technique carried out in the field is
considered industry best standard practice and was completed by
the geologist.
All samples were dry
Samples collected at 1 metre intervals from a cyclone-mounted
cone splitter to yield a 2 to 3 kg sub-samples, collected in the field,
and sent to Intertek Kalgoorlie for receival then sorted and recorded.
Individual samples were weighed as received and then dried in an
oven for up to 12 hours at 105C.
Samples >3 kg’s were riffle split 50:50 and excess discarded. All
samples were then pulverised in a LM5 pulveriser for 5 minutes to
achieve 85% passing 75um. 1:50 grind checks were performed to
verify passing was achieved.
A 300g split was taken at the bowl upon completion of the grind and
sent to the next facility for assay. The remainder of the sample (now
pulverised) was bagged and retained until further notice.
For each submitted sample, the remaining coarse sample (material)
less the aliquot used for analysis has been retained, with the majority
retained and returned to the original calico bag and a nominal 100g
portion split into a pulp packet for future reference.
ABN 77 648 687 094
Level 4, 220 St Georges Tce
Perth, WA 6000
PO BOX 7713
Cloisters Square WA 6850
T: +61 8 6381 7250
F: +61 8 6381 7299
info@widgienickel.com.au
www.widgienickel.com.au
11
ASX Announcement
26 October 2023
Quality of
assay data
and
laboratory
tests
Section 1 Sampling Techniques and Data
Quality control procedures adopted for all subWidgie Nickel has established QAQC procedures for all drilling and
sampling stages to maximise representivity of
sampling programs including the use of commercial Certified
samples.
Reference Material (CRM) as field and laboratory standards, field
and laboratory duplicates and blanks.
Measures taken to ensure that the sampling is
Lithium CRM samples have been inserted into the batches by the
representative of the in-situ material collected,
geologist, at a nominal rate of 5% of the total samples.
including for instance results for field
duplicate/second-half sampling.
Field duplicate samples have been taken in visibly mineralised
zones, at a rate of 2% of total samples.
Whether sample sizes are appropriate to the grain
size of the material being sampled.
Samples of blank material have been submitted immediately after
visibly mineralised zones at a nominal rate of 5% of the total
The nature, quality and appropriateness of the
samples.
assaying and laboratory procedures used and
whether the technique is considered partial or total.
Sample size is considered appropriate to the grain size of the
material being sampled.
For geophysical tools, spectrometers, handheld
XRF instruments, etc, the parameters used in
Samples were analysed at Intertek Perth, WA.
determining the analysis including instrument make
and model, reading times, calibrations factors
Primary samples were assayed for lithium only via a four-acid digest.
applied and their derivation, etc.
With an Inductively Coupled Plasma Optical Emission Spectrometry
(ICP-OES) finish for Lithium only
Nature of quality control procedures adopted (e.g.,
standards, blanks, duplicates, external laboratory
3,371 samples were subjected to comparison analysis were assayed
checks) and whether acceptable levels of accuracy
for lithium via a sodium peroxide fusion using nickel crucibles and
(i.e. lack of bias) and precision have been
hydrochloric acid to digest. With an Inductively Coupled Plasma
established.
Optical Emission Spectrometry (ICP-OES) finish.
Internal sample quality control analysis was then conducted on each
sample and on the batch by the laboratory.
Results have been reported to Widgie Nickel in CSV, PDF and SIF
formats.
Verification
of sampling
and
assaying
The verification of significant intersections by either
independent or alternative company personnel.
The use of twinned holes
The verification of significant intersections by either
independent or alternative company personnel.
Discuss any adjustment to assay data
A detailed QAQC analysis was carried out with all results assessed
for repeatability and meeting expected values
Share your feedback
Discover